Kruess Optronic FP8000 series Laboratory Flame Photometer
Measure up to four alkaline elements simultaneously
The Kruess FP8000 series Flame Photometer system offers simple, precise, cost-effective measurement in industrial applications it includes an optional 89 sample position auto-sampler, diluter and mixer for fast simultaneous multi element measurement.
Ideal for concentrated alkaline elements in aqueous solution, the four measuring channels include Sodium, Potassium, Lithium and Calcium, the FP8000 series will deliver a rate of around 300 samples per hour. A unique feature world-wide!
Utilising purified, dried air and propane, butane or acetylene as a fuel gas, the FP8000 series gives flame-photometric measuring of the four elements simultaneously, allows 99 definable methods, and stores the last 999 measurement results. The device can be easily customised to suit user requirements, and for traceability of results, it has the facility to export data via USB port, RS232 or ethernet interface for computer aided statistical process control.
The FP8000 series has four independent measuring channels and an additional separate channel for the monitoring of the flame. Each of these channels can be equipped with the appropriate optical filters. The FP8000 series does not require a spectral reference line, although measurement operation can be carried out either with or without a reference element.
This established and proven measurement technique in combination with modern instrument electronics and innovative process control makes the FP8000 series an essential component of measurement for many applications in a broad range of industries.
Features & Specifications
Economic, robust, safe and long-lasting measuring instrument
Simple, precise and cost-efficient measuring method for the simultaneous determination of alkali and alkaline earth element concentrations in aqueous samples
Precision: < 0.2% with 40 mg/l Na, K, Li and Ca standard solution
Accuracy: < 1% with 40 mg/l Na, K, Li and Ca standard solution
99 freely definable methods
999 result data sets in a ring buffer
Interfaces: 1x Ethernet (LAN, LIMS) 1x RS-232 (Printer) 2x USB (mouse, data export, firmware update)
Touch Screen , 800 x 600 pixels. Complete user management, SQL data base, export of measured data to Excel
Automatic measuring when connected to autosampler, diluter and mixer
Full cGMP/GLP compatibility
Meets all the requirements of international standards such as 21 CFR part 11, Pharmacopoeia, OIML and ASTM
For more information and full technical specifications please download our FP8000 series product brochure or visit the KRUESS website
Additional information
Manufacturer
KRUESS Optronic
Industry
Biofuels, Energy – Oil, Gas and Petrochemicals, Environmental, Food, Flavour and Beverage, Forensics, Fragrance and Essential Oils, Pharamceuticals and Life Science, Recycling – Fuels from Waste
Kruess Optronic FP8000 series Laboratory Flame Photometer
Measure up to four alkaline elements simultaneously
The Kruess FP8000 series Flame Photometer system offers simple, precise, cost-effective measurement in industrial applications it includes an optional 89 sample position auto-sampler, diluter and mixer for fast simultaneous multi element measurement.
Ideal for concentrated alkaline elements in aqueous solution, the four measuring channels include Sodium, Potassium, Lithium and Calcium, the FP8000 series will deliver a rate of around 300 samples per hour. A unique feature world-wide!
Description
Overview
Utilising purified, dried air and propane, butane or acetylene as a fuel gas, the FP8000 series gives flame-photometric measuring of the four elements simultaneously, allows 99 definable methods, and stores the last 999 measurement results. The device can be easily customised to suit user requirements, and for traceability of results, it has the facility to export data via USB port, RS232 or ethernet interface for computer aided statistical process control.
The FP8000 series has four independent measuring channels and an additional separate channel for the monitoring of the flame. Each of these channels can be equipped with the appropriate optical filters. The FP8000 series does not require a spectral reference line, although measurement operation can be carried out either with or without a reference element.
This established and proven measurement technique in combination with modern instrument electronics and innovative process control makes the FP8000 series an essential component of measurement for many applications in a broad range of industries.
Features & Specifications
For more information and full technical specifications please download our FP8000 series product brochure or visit the KRUESS website
Additional information
KRUESS Optronic
Biofuels, Energy – Oil, Gas and Petrochemicals, Environmental, Food, Flavour and Beverage, Forensics, Fragrance and Essential Oils, Pharamceuticals and Life Science, Recycling – Fuels from Waste
Flame Photometry
Brochure
Kruess Flame Photometer Product Brochure
Kruess Flame Photometer Product Overview
Kruess Product Overview
Video
Application Notes